Home | About us | Editorial Board | Search | Ahead of print | Current Issue | Archives | Instructions | Online submissionContact Us   |  Subscribe   |  Advertise   |  Login  Page layout
Wide layoutNarrow layoutFull screen layout
Lung India Official publication of Indian Chest Society  
  Users Online: 633   Home Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2021  |  Volume : 38  |  Issue : 2  |  Page : 109-116

Safety and diagnostic yield of transbronchial lung cryobiopsy by flexible bronchoscopy using laryngeal mask airway in diffuse and localized peripheral lung diseases: A single-center retrospective analysis of 326 cases


1 Department of Pulmonology, Critical Care and Sleep Medicine, Fortis Memorial Research Institute, Gurugram, Haryana, India
2 Department of Anesthesiology, Fortis Memorial Research Institute, Gurugram, Haryana, India
3 Department of Pathology, Fortis Memorial Research Institute, Gurugram, Haryana, India
4 Department of Radiology, Fortis Memorial Research Institute, Gurugram, Haryana, India

Correspondence Address:
Dr. Manoj Kumar Goel
Department of Pulmonology, Critical Care and Sleep Medicine, Fortis Memorial Research Institute, Sector 44, Gurugram - 122 002, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/lungindia.lungindia_220_20

Rights and Permissions

Background: Intubation with either an endotracheal tube or a rigid bronchoscope is generally preferred to provide airway protection as well as to manage unpredictable complications during transbronchial lung cryobiopsy (TBLC). The laryngeal mask airway has been described as a safe and convenient tool for airway control during bronchoscopy. Aims and Objectives: In this study, we evaluated the safety and outcome of using a laryngeal mask airway (LMA) as a conduit for performing TBLC by flexible video bronchoscopy (FB). Methods: We retrospectively analyzed the database of the patients who underwent TBLC between November 2015 and September 2019. The procedure was performed using FB through LMA under general anesthesia. Prophylactic occlusion balloon was routinely used starting January 2017 onwards. Radial endobronchial ultrasound (R-EBUS) guidance was used for TBLC in the localized lung lesions when deemed necessary. Multidisciplinary consensus diagnostic yield was determined and periprocedural complications were recorded. Results: A total of 326 patients were analysed. The overall diagnostic yield was 81.60% (266/326) which included a positive yield of 82.98% (161/194) in patients with diffuse lung disease and 79.54% (105/132) in patients with localized disease. Serious bleeding complication occurred in 3 (0.92%) cases. Pneumothorax was encountered in 8 (2.45%) cases. A total of 9 (2.76%) cases had at least 1 major complication. Conclusion: This study demonstrates that the use of LMA during TBLC by flexible bronchoscopy allows for a convenient port of entry, adequate airway support and effective endoscopic management of intrabronchial haemorrhage especially with the use of occlusion balloon.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed740    
    Printed8    
    Emailed0    
    PDF Downloaded170    
    Comments [Add]    

Recommend this journal